HOT ITEM | HOT ITEM | | | S5134 : 8 -CH 0- 5V,0 -10V,4 - 20mA analog inputs,3-CH isolated DI, 8-CH isolated open-collector outputs , 8-CH 0-10V analog output module ,Ethernet/RS485,Modbus TCPIP/Modbus protocol | S5138 : 8 -CH 0- 5V,0 -10V,4 - 20mA analog inputs,6-CH isolated DI, 16-CH isolated open-collector outputs ,,Ethernet/RS485,Modbus TCPIP/Modbus protocol | - Surge-protected analog inputs with 12-bit resolution and 100k sample speed
- Input can be any combination of 0-10V,0-5V,4-20mA,NTC 10K thermistor and dry contact
- The channel number is configurable, can be set up from 1 channel through 8 channels, for analog input and set up from 1 to 3 for digital input, improve sample rate for small count input
- 8 channels 0-10V analog output with high accurate reference chip
- 3 channels Isolated digital inputs can be configured as counter input, total 32 bits,1000Hz
- Total 8 channels isolated open-collector output
- Standard ModBus TCPIP protocol,easy work with PLC
- Surge-protected and isolated Rs485 ensure reliability
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- A lot of spare FLASH can be used to store user’s parameters
- White and black encloure available ,DIN rail
| - Surge-protected analog inputs with 12-bit resolution and 100k sample speed
- Input can be any combination of 0-10V,0-5V,4-20mA,NTC 10K thermistor and dry contact
- The channel number is configurable, can be set up from 1 channel through 8 channels, for analog input and set up from 1 to 6 for digital input, improve sample rate for small count input
- 6 channels Isolated digital inputs can be configured as counter input, total 32 bits,1000Hz
- Total 16 channels isolated open-collector output
- Standard ModBus TCPIP protocol,easy work with PLC
- Surge-protected and isolated Rs485 ensure reliability
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- A lot of spare FLASH can be used to store user’s parameters
- White and black encloure available ,DIN rail
| Technical_S5134.zip | Technical_S5138.zip | Price: $145 | Price: $115 | | | S5102 : 8 -CH 0- 5V,0 -10V,4 - 20mA analog inputs,6-CH isolated DI, 12-CH relay outputs , 2-CH 0-10V analog output module | S5140 : 40 channels 0- 5V,4 - 20mA,10K NTC thermistor,dry contact analog inputs module | - Surge-protected analog inputs with 12-bit resolution and 100k sample speed
- Input can be any combination of 0-10V,0-5V,4-20mA,NTC 10K thermistor and dry contact
- The channel number is configurable, can be set up from 1 channel through 8 channels, for analog input and set up from 1 to 6 for digital input, improve sample rate for small count input
- 2 channels 0-10V analog output with high accurate reference chip
- Isolated digital inputs can be configured as counter input, total 32 bits,1000Hz
- Total 12 channels relay output,mormal open contact
- Surge-protected and isolated Rs485 ensure reliability
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- A lot of spare FLASH can be used to store user’s parameters
- White and black encloure available ,DIN rail
| - Surge-protected analog inputs with 12-bit resolution and 100k sample speed
- Input can be any combination of 0-10V,0-5V,4-20mA,NTC 10K thermistor and dry contact
- Surge-protected and isolated Rs485 ensure reliability
- The channel number is configurable, can be set up from 1channel through 40 channels, improve sample rate for small count analog input
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- A lot of spare FLASH can be used to store user’s parameters
- White and black encloure available ,DIN rail
| Technical_S5102.zip | Technical_S5140.zip | Price: $109 | Price: $89 | HOT ITEM | HOT ITEM | | | S5301 : 24 channels isolated digtial input and 16 channels open-collector digtial output module | S5302 : 40 channels isolated DRY/WET contact digital input module | - Isolated digital inputs can be configured as counter input, total 32 bits,5000Hz
- Can measure frequency from 0 to 1000Hz,the resolution is 0.1Hz
- Accept reed and hall sensor output from water meter or other meters
- Static and lightning protection for each input
- The input channel number is configurable, can be set up from 1 channel through 24 channels, improve frequency for small count input
- Isolated open-collector output can drive power relay directly
- Surge-protected and isolated Rs485 ensure reliability
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- A lot of spare FLASH can be used to store user’s parameters
- White and black encloure available ,DIN rail
| - Isolated digital inputs can be configured as counter input, total 32 bits,5000Hz
- Can measure frequency from 0 to 1000Hz,the resolution is 0.1Hz
- Accept reed and hall sensor output from water meter or other meters
- Static and lightning protection for each input
- The input channel number is configurable, can be set up from 1 channel through 40 channels, improve frequency for small count input
- Surge-protected and isolated Rs485 ensure reliability
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- A lot of spare FLASH can be used to store user’s parameters
- White and black encloure available ,DIN rail
| Technical_S5301.zip | Technical_S5302.zip | Price: $89 | Price: $89 | RS485 Modules <-- > More | Ethernet Modules <-- > More | | | S5100 : 8 channels 0- 5V,0 -10V,4 - 20mA analog inputs,10 relay outputs ,12bits ADC | S6116: Ethernet 16 chananels analog input modules 0-5V, 0-10V, 4-20mA, dry contact, 10K NTC thermistor inputs ,12-bit ADCs, Modbus/TCPIP and Modbus protocol | - Surge-protected analog inputs with 12-bit resolution and 100k sample speed
- Input can be any combination of 0-10V,0-5V,4-20mA,NTC 10K thermistor and dry contact
- 10 channel normal open relay outputs, each output channel can be set AUTO/OFF/HAND by a 3-states switch
- Surge-protected and isolated Rs485 ensure reliability
- The channel number is configurable, can be set up from one channel through eight channels, improve sample rate for small count analog input
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- White and black encloure available
| - Surge-protected analog inputs with 12-bit resolution and 100k sample speed
- Input can be any combination of 0-10V, 0-5V, 4-20mA, NTC 10K thermistor and dry contact
- The channel number is configurable, can be set up from one channel through eight channels, improve sample rate for small count analog input
- A lot of spare FLASH can be used to store user’s parameters
- Standard MODBUS/TCPIP protocol for Ethernet and standard MODBUS protocol for RS485
- DIN support available
| Technical_S5100.zip | Technical_S6116.zip | Modbus_Protocol.pdf | Modbus_Protocol.pdf | Price: $115 | Price: $80 | Zigbee Modules <-- > More | RTD Modules | | | S7106: 4 channels 0- 5V, 0 -10V, 4 - 20mA analog inputs, 12bits ADC,2 channels relay output(220VAC/3A) Modbus RTU/ASCII, Zigbee wireless | S3600: 4 channels 3-wire RTD input,RS485 ,MODBUS/RTU,MODBUS/ASCII | - Surge-protected analog inputs with 12-bit resolution and 100k
sample speed - Input can be any combination of 0-10V,0-5V,4-20mA,NTC 10K
thermistor and dry contact - Accept 0-50Hz pulse input and store pulse counter in Flash
- 2 channesl relay output (220VAC/3A) and 1channel 0-5V analog output
- Can measure the power supply voltage
- Reliable Zigbee can up to 2000 meters communication
- The channel number is configurable, can be set up from 1 channel
through 4 channel, improve sample rate for small count analog input - Standard ModBus protocol allows for up to 254 unique devices on
one network - A lot of spare FLASH can be used to store user’s parameters
- Can detect RS232 or ZIGBEE automatically, no need jumper
- You can tell us your requirement. we will update our firmware
even after you received the modules ,you can update your modules through ISP.
| - Surge-protected RTD inputs with 16-bit resolution and 100k sample speed
- 3-Wire to avoid resistance affect accuracy
- Different RTD sensor available
- Different temperature range available
- Surge-protected and isolated Rs485 ensure reliability
- Standard ModBus protocol allows for up to 254 unique devices on one RS485 network
- A lot of spare FLASH can be used to store user’s parameters
- Can update your firmware via ISP through RS485 network
| Technical_S7106.zip | Technical_S3600.zip | Modbus_Protocol.pdf | Modbus_Protocol.pdf | Price: $100 | Price: $69 |
|